ORA-16672: some switchover databases need to be restarted manually
Cause:
An error occurred during the restart of either the old and the new primary databases or both in a switchover operation.
Action:
Manually restart both the old and new primary databases, including all their Oracle RAC instances if it is an Oracle RAC database.